TEG Regeneration
Client: | HEAT |
Location: | Austria |
Date: | 2023 |
Scope of Work: | Purchasing of material, manufacturing, assembling, testing and painting of TEG regeneration |
Equipment Type: | TEG Regeneration Unit |
Project Details
- TEG-Regeneration Vessels: DN1400 Reboiler, DN350 Column, DN600 Condenser, DN300 Stack
- Included in Complete TEG System:
- ↳ Reboiler DN1400 incl. DN1200 tank
- ↳ Heating register DN500
- ↳ Column DN350
- ↳ Condenser DN600
- ↳ Stack DN300
- Design Pressure (without pipe coil): 0.5 bar(g); Test pressure 1.5 bar(g)
- Design Pressure of DN50 pipe coil: 4 bar(g); Test pressure 6 bar(g)
- Design Temperature: -20 / +250 °C
- Corrosion Allowance: 3 mm
- Design Code: EN 13445
- Coating (Insulated Part): Heat resistant primer (TEMASIL90 70μm + TEMAL600HB 20μm)
- Coating (Non-insulated Part): Heat resistant coating; C3-H acc. ISO 12944; 200 μm